Items | Method | Condition | Unit | Typical Value | |
---|---|---|---|---|---|
Tg | IPC-TM-650 2.4.25 | DSC | ℃ | 130 | |
Td | IPC-TM-650 2.4.24.6 | 5% wt. loss | ℃ | — | |
CTE (Z-axis) | IPC-TM-650 2.4.24 | Before Tg | ppm/℃ | 60 | |
After Tg | ppm/℃ | 340 | |||
50-260℃ | % | 5.2 | |||
Thermal Stress | IPC-TM-650 2.4.13.1 | 288℃, solder dip | -- | 30S No delamination | |
Volume Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ.cm | 2.9 x 108 | |
E-24/125 | MΩ.cm | 8.6 x 106 | |||
Surface Resistivity | IPC-TM-650 2.5.17.1 | After moisture resistance | MΩ | 2.8 x 107 | |
E-24/125 | MΩ | 4.8 x 106 | |||
Arc Resistance | IPC-TM-650 2.5.1 | D-48/50+D-4/23 | s | 115 | |
Dielectric Breakdown | IPC-TM-650 2.5.6 | D-48/50+D-4/23 | kV | 45+kV NB | |
Dissipation Constant (Dk) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 4.6 | |
| | | |||
Dissipation Factor (Df) | IPC-TM-650 2.5.5.9 | 1MHz | -- | 0.016 | |
| | | | ||
Peel Strength(1Oz HTE copper foil) | IPC-TM-650 2.4.8 | A | N/mm | — | |
After thermal Stress 288℃,10s | N/mm | 1.9 | |||
125℃ | N/mm | 1.7 | |||
Flexural Strength | LW | IPC-TM-650 2.4.4 | A | MPa | 400 |
CW | IPC-TM-650 2.4.4 | A | MPa | 320 | |
Water Absorption | IPC-TM-650 2.6.2.1 | E-1/105+D-24/23 | % | 0.11 | |
CTI | IEC60112 | A | Rating | PLC 3 | |
Flammability | UL94 | C-48/23/50 | Rating | V-0 | |
E-24/125 | Rating | V-0 |
Remarks:
1. Specification sheet: IPC-4101/12, is for your reference only.
2. All the typical value is based on the 1.6mm specimen.
3. All thetypical values listed above are for your reference only and not intended forspecification. Please contact Shengyi Technology Co., Ltd. for detailedinformation. All rights from this data sheet are reserved by Shengyi TechnologyCo., Ltd.
Explanation:C=Humidity conditioning, D=Immersion conditioning in distilled water,E=Temperature conditioning
Thefirst digit following the letter indicates the duration of preconditioning inhours, the second digit the preconditioning temperature in ℃ andthe third digit the relative humidity.